Analysis of the causes of concrete slump loss

Recently, covid 19 outbreak spreads in Shanghai, China. There are more than 25,000 new asymptomatic domestic infections every day. China is implementing a dynamic zero-out policy. A leading respiratory expert said the key to COVID-19 prevention and control is to minimize transmission and fatality rate. Omicron has a low case fatality rate but is highly transmissible and can still claim many lives in large outbreaks. "Total openness is not applicable in China.  For China, we should keep to the dynamic zero-out and gradually open up."  

However, "dynamic zero clearance" is not the pursuit of complete "zero infection".  As the Novel Coronavirus has its own uniqueness and strong concealment, there may be no way to prevent the detection of cases at present, but rapid detection and prompt treatment must be carried out, as soon as one case is found, one case will be dealt with.  

The situation in Shanghai is serious. As the financial center of China, Shanghai is a very important city, and the outbreak of the epidemic in Shanghai will put a great impact on China's economy.  The current task is to contain the spread of the epidemic as soon as possible, to achieve social zero so that Shanghai's life and economy quickly return to normal.  

As China plays an important role in the global supply chain, the outbreak will have a significant impact on the supply and prices of many concrete slump.

There are many reasons for slump loss, mainly in the following aspects:

1. Influence of raw materials

Whether the cement used and the pumping agent are matched and adapted must be obtained through the adaptability test. The optimum amount of the pumping agent should be determined through the adaptability test with the cement cementitious material. The amount of air-entraining and retarding components in the pumping agent has a greater impact on the loss of concrete slump. If there are many air-entraining and retarding components, the slump loss of concrete will be slow, otherwise the loss will be fast. The slump loss of concrete prepared with naphthalene-based superplasticizer is fast, and the loss is slow when the low positive temperature is below +5 °C.

If anhydrite is used as the setting modifier in the cement, the slump loss of the concrete will be accelerated, and the early strength component C3A content in the cement is high. If "R" type cement is used, the cement fineness is very fine, and the cement setting time is fast, etc. It will cause the slump loss of concrete to accelerate, and the speed of concrete slump loss is related to the quality and amount of mixed materials in the cement. The C3A content in the cement should be within 4% to 6%. When the content is lower than 4%, the air-entraining and retarder components should be reduced, otherwise the concrete will not solidify for a long time. When the C3A content is higher than 7%, it should be increased. Air-entraining retarder component, otherwise it will cause rapid loss of concrete slump or false setting phenomenon.

The mud content and mud block content of the coarse and fine aggregates used in concrete exceed the standard, and the content of crushed stone needle flake particles exceeds the standard, which will cause the slump loss of concrete to accelerate. If the coarse aggregate has a high water absorption rate, especially the crushed stone used, after being exposed to high temperature in the summer high temperature season, once it is put into the mixer, it will absorb a large amount of water in a short period of time, resulting in accelerated slump loss of the concrete in a short time (30min). 


2 Influence of stirring process

The concrete mixing process also affects the slump loss of concrete. The model of the mixer and the mixing efficiency are related. Therefore, the mixer is required to be regularly repaired and the mixing blades should be replaced regularly. Concrete mixing time should not be less than 30s. If it is less than 30s, the slump of concrete is unstable, resulting in relatively accelerated slump loss.


3 Temperature effects

The effect of temperature on the slump loss of concrete is of particular concern. In hot summer, when the temperature is higher than 25°C or above 30°C, the concrete slump loss will be accelerated by more than 50% compared with that at 20°C. When the temperature is lower than +5°C, the concrete slump loss will be very small or not lost. . Therefore, during the production and construction of pumped concrete, pay close attention to the influence of air temperature on the slump of concrete.

The high use temperature of the raw materials will cause the concrete to increase in temperature and accelerate the slump loss. It is generally required that the concrete discharge temperature should be within 5 ~ 35 ℃, beyond this temperature range, it is necessary to take corresponding technical measures, such as adding cold water, ice water, groundwater to cool down and heat the water and the use temperature of raw materials and so on.

It is generally required that the maximum operating temperature of cement and admixtures should not be higher than 50 °C, and the operating temperature of concrete pumped heating water in winter should not be higher than 40 °C. There is a false coagulation state in the mixer, and it is difficult to get out of the machine or transport it to the site for unloading.

The higher the temperature of the cementitious materials used, the worse the water-reducing effect of the water-reducing components in the pumping agent on concrete plasticization, and the faster the concrete slump loss. The concrete temperature is proportional to the slump loss, and the slump loss can reach about 20-30mm when the concrete increases by 5-10℃.


4 Strength levels

The slump loss of concrete is related to the strength grade of concrete. The slump loss of concrete with high grade is faster than that of low-grade concrete, and the loss of crushed stone concrete is faster than that of pebble concrete. The main reason is that it is related to the amount of cement per unit.


5 Concrete state

Concrete statically loses slump faster than dynamic. In the dynamic state, the concrete is continuously stirred, so that the water-reducing components in the pumping agent cannot fully react with the cement, which hinders the progress of cement hydration, so that the slump loss is small; in the static state, the water-reducing components are fully in contact with the cement, The cement hydration process is accelerated, so the concrete slump loss is accelerated.


6 Transport machinery

The longer the transportation distance and time of the concrete mixer truck, the less free water of the concrete clinker due to chemical reaction, water evaporation, water absorption of the aggregate and other reasons, resulting in the loss of concrete slump over time. The barrel also causes mortar loss, which is also an important cause of concrete slump loss.


7 Pour speed and time

In the process of concrete pouring, the longer the time for the concrete clinker to reach the silo surface, the rapid reduction of free water in the concrete clinker due to chemical reactions, water evaporation, aggregate water absorption and other reasons, resulting in slump loss. , especially when the concrete is exposed on the belt conveyor, the contact area between the surface and the external environment is large, and the water evaporates rapidly, which has the greatest impact on the slump loss of the concrete. According to the actual measurement, when the air temperature is around 25℃, the on-site slump loss of concrete clinker can reach 4cm within half an hour.

Concrete pouring time is different, which is also an important cause of concrete slump loss. The impact is small in the morning and evening, and the impact is greater at noon and afternoon. The temperature in the morning and evening is low, the water evaporation is slow, and the temperature in the afternoon and afternoon is high. The worse the fluidity and cohesion, the more difficult it is to guarantee the quality.


TRUNNANO is a concrete additives supplier with over 12 years experience in nano-building energy conservation and nanotechnology development. We accept payment via Credit Card, T/T, West Union and Paypal. Trunnano will ship the goods to customers overseas through FedEx, DHL, by air, or by sea.

If you are looking for high quality concrete superplasticizer, please feel free to contact us and send an inquiry.

sales@cabr-concrete.com




The Free Trade Agreement between India and the United Arab Emirates (UAE) has come into force on.

The UAE is the gateway to the Middle East, North Africa, Central Asia, and sub-Saharan Africa, said Subramaniam, a senior official at India's Ministry of Commerce and Industry.  The agreement will help boost bilateral trade in goods from $60 billion a year now to $100 billion a year within five years.

On 18 February 2022, India and the United Arab Emirates signed the Comprehensive Economic Partnership Agreement. With the entry into force of the agreement, 90 percent of Indian goods and 65 percent of UAE goods will enjoy tariff-free market access.

Apart from its FTA with the UAE, India is also pursuing FTAs with Australia, the UK, Canada, Israel, the European Union, and the Gulf Cooperation Council.

Influenced by international situations, the supply and prices of many concrete slump are still very uncertain.

Inquiry us

Our Latest Answers

What is amorphous boron?

Amorphous boron is a material that has a non-crystalline structure and does not have a distinct plan of atoms. This contrasts crystalline boron, which has a highly routine, purchased structure.To create amorphous boronHigh pureness Amorphous Boron Ma…

Where is Zinc stearate used in

Zinc stearate is mainly used as lubricating substance and also launch representative of styrene resin, phenolic material and also amino material, in addition to vulcanizing active agent and conditioner in rubber.What is Zinc stearate made use of for?…

What is Alumina Nanoparticle used for

Lithium battery diaphragm coating product:High pureness nano alumina is put on the favorable and unfavorable diaphragm of lithium battery as a ceramic layer, which plays the function of warm resistance, high temperature resistance and insulation, so…